Quattroflow 1200SU

PSG BiotechQF1200SU-HTQF1200SUQF1200SU OEM

QF1200SU-HT

  • Integrated pump chamber, pump drive, motor and control box
  • Extended turndown ratio
  • Flexible single-phase 110-23V power supply

QF1200SU

  • Disposable wetted pump chamber
  • Pump chamber made of solid polypropylene
  • AC motor for operation for external VFD

QF1200SU-M

  • Pump chamber made of injection-molded polyethylene
  • Front side connections

QF1200SU OEM

  • OEM design for easy skid integration
  • Extended turndown ratio
  • Global power supply and motor certification
  • Multiple accessories (VFD, Cable, Gasket) available
  • Flange adapters for additional motor types available

Technical Data

STANDARD MOTORQF1200SUQF1200SU-MQF1200SU-HTQF1200SU OEM
Flow Rate MaximumEccentric Shaft 3°800 lph (13.3 lpm)800 lph (13.3 lpm)800 lph (13.3 lpm)800 lph (13.3 lpm)
 
Eccentric Shaft 5°1200 lph (20 lpm)1200 lph (20 lpm)1200 lph (20 lpm)1200 lph (20 lpm)
Flow Rate Minimum*Eccentric Shaft 3°10 lph (0.167 lpm)10 lph (0.167 lpm)10 lph (0.167 lpm)10 lph (0.167 lpm)
Eccentric Shaft 5°20 lph (0.333 lpm)20 lph (0.333 lpm)6 lph (0.1 lpm)6 lph (0.1 lpm)
PressureTemperature of Fluid < 40°C (104°F)4 bar (58 psi)4 bar (58 psi)4 bar (58 psi)4 bar (58 psi)
Temperature of Fluid > 40°C (104°F)4 bar (58 psi)4 bar (58 psi)4 bar (58 psi)4 bar (58 psi)
Maximum TemperatureFluid60°C (140°F)50°C (122°F)60°C (140°F)60°C (140°F)
Autoclave130°C (266°F)130°C (266°F) 130°C (266°F)130°C (266°F)
Pump Speed Rangerpm30 – 2,40030 – 2,40010 – 2,40010 – 2,400 
Suction Lift Dry at 1800 rpmEccentric Shaft 3°2.5 – 3 m (8.2-9.8 ft)2-2.5 m (6.6-8.2 ft)--
Eccentric Shaft 5°4 – 4.5 m (13.1-14.7 ft)3-3.5 m (9.8-11.5 ft)4 – 4.5 m(13.1-14.7 ft)4 - 4.5 m (13.1 - 14.7 ft)
Volume SpecificationsApproximated Volume per
Revolution at Free Output
9.6 ml (5°)5.8 ml (3°)9.6 ml (5°)5.8 ml (3°)9.6 ml (5°)9.6 ml
Filling Volume Without Connectors75 ml75 ml75 ml75 ml
Connection Specification (Standard)Connectors3/4" TC3/4" TC3/4" TC3/4" TC
Position of ConnectorsInlineFrontInlineInline
Number of Flow Directions444
Product Wetted Materials (Standard)Pump ChamberPPPE injection molded**PPPP
Valve PlatePPPE injection moldedPPPP
DiaphragmsTPETPETPETPE
ValvesEPDMEPDMEPDMEPDM
O-ringsEPDMEPDMEPDMEPDM
Certificates/Proofs (Optional)Elastomere (product wetted)USP <88> Cl. VI; FDA21CFR177;
BSE/TSE Safe; USP 87/381/661
USP <88> Cl. VI; FDA21CFR177;
BSE/TSE Safe; USP 87/381/661
USP <88> Cl. VI; FDA21CFR177;
BSE/TSE Safe; USP 87/381/661
USP <88> Cl. VI; FDA21CFR177;
BSE/TSE Safe; USP 87/381/661
Motor (Standard)Rated speed1375 min-1 (50 Hz)1375 min-1 (50 Hz)2200 min-12400 min-1
Voltage230/400 V230/400 V110 – 230 V3 x 230V / 3 x 400V
Power0.37 kW0.37 kW0.485 kW-
Pump Dimension with Motor and HousingLength497 mm (19.56")503 mm (19.8")499 mm (19.65")387 mm (15.24")
Width159 mm (6.26")159 mm (6.26")200 mm (7.87")159 mm (6.26")
Height210 mm (8.27")210 mm (8.27")220 mm (8.66")163 mm (6.42")
Pump Weight with Motor and Housing 21 kg (46 lb)20 kg (44 lb)21 kg (46 lb)13.6 kg (30 lb)

Other connection specifications, materials and motors available on request.
* When using pump with control box 20 lph (0.333 lpm) and 40 lph (0.667 lpm)
** Connectors PP

Performance

Click on the images to enlarge.

Quattroflow Biopharma Pump QF1200SU Single-Use Performance Chart

QF1200SU Eccentric Shaft 5° – Liter

Quattroflow Biopharma Pump QF1200SU Single-Use Performance Chart

QF1200SU Eccentric Shaft 5° – Gallon

Quattroflow Biopharma Pump QF1200SU-M Single-Use Performance Chart

QF1200SU-M Eccentric Shaft 5° – Liter

Quattroflow Biopharma Pump QF1200SU-M Single-Use Performance Chart

QF1200SU-M Eccentric Shaft 5° – Gallon

Quattroflow Biopharma Pump QF1200SU-HT Single-Use Performance Chart

QF1200SU-HT Eccentric Shaft 5° – Liter

Quattroflow Biopharma Pump QF1200SU-HT Single-Use Performance Chart

QF1200SU-HT Eccentric Shaft 5° – Gallon

Downloads